Powershield PSCRT2000 Commander RT 2000VA/1800W UPS. Line interactive pure sine wave output. Rack/Tower
With pure sine wave output, the Commander Rackmount Tower guarantees compatibility for all kinds of loads. It’s perfect power protection for versatile applications such as networking, telecom and other mission-critical applications.
The ECO mode function allows cost-effective operation of UPS Systems as high as 98%. In this operation mode, load is supplied by the mains. In the event of a mains failure, the inverter takes over the load and provides supply continuity to the connected systems.
- Pure sine wave output
- Rack/Tower design
- Built-in boost and buck AVR
- Output power factor 0.9
- Programmable power management outlets
- ECO mode operation for energy saving (ECO)
- Emergency Power Off Function (EPO)
- Hot-swappable battery design
- Long-run models available
- Multiple communication available
- 2 Year Warranty
Multiple communication available:
USB port
RS-232 port
SNMP slot (option)
AS400 card (option)
PowerShield NetGuard® software included.
Capacity |
2000VA/1800W |
Topology |
Line Interactive, Pure Sine Wave |
Input |
|
Voltage |
240Vac (Nominal) |
Voltage Range |
162-290V ac |
Frequency Range |
50/60Hz (Auto-sensing) ±5Hz |
Output |
|
Output Voltage (AC Mode) |
240V ac (Selectable 208/220/230Vac) ±10% AVR |
Voltage Regulation (Batt. Mode) |
±3% |
Frequency Range (Batt. Mode) |
50Hz or 60Hz ±1Hz |
Current Crest Ratio |
3:1 |
Transfer Time |
6ms (Typical) |
Waveform (Batt. Mode) |
Pure Sine Wave |
Efficiency |
|
ECO Mode (Advanced) |
98% |
Battery Mode |
89% |
Battery |
|
Standard Model |
Battery Type & Number: 12V x 9AH (x 4) |
Additional Battery Banks |
PSRTBB8 (x1) |
Protection |
|
Full Protection |
Overload, discharge, thermal, short circuit and overcharge protection |
Surge Protection |
1560J/32500A |
Communications & Management |
|
Interface |
USB or RS232 as standard, Intelligent slot for PSSNMP, PSModbus or PSAS400 dry contact |
Software |
PowerShield NetGuard® software - supports Windows based operating systems, Linux, Unix and Mac |
LCD Display/Alarm |
AC Mode, Batt.Mode, Load Level, Input Voltage, Output Voltage, Overload, Fault, Low Batt, Batt.Time Remaining |
Audible Alarm |
Battery Mode, Low Battery (Batt. Mode), Fault, Overload |
Physical |
|
Dimension (D x W x H) |
480 x 438 x 88mm |
Weight (Net/Gross) |
(23kg/25kg) |
Operating Environment |
|
Temperature |
0 - 40°C |
Humidity |
0 - 90% (RH Non-condensing) |
Noise Level |
<45dB |
Compliance |
|
Safety |
EN62040-1-1 2003, IEC60950-1-1 |
EMC |
EN62040-2 2006 |
RoHS |
Directive 2011/65/EU |
Capacity |
2000VA/1800W |
Topology |
Line Interactive, Pure Sine Wave |
Input |
|
Voltage |
240Vac (Nominal) |
Voltage Range |
162-290V ac |
Frequency Range |
50/60Hz (Auto-sensing) ±5Hz |
Output |
|
Output Voltage (AC Mode) |
240V ac (Selectable 208/220/230Vac) ±10% AVR |
Voltage Regulation (Batt. Mode) |
±3% |
Frequency Range (Batt. Mode) |
50Hz or 60Hz ±1Hz |
Current Crest Ratio |
3:1 |
Transfer Time |
6ms (Typical) |
Waveform (Batt. Mode) |
Pure Sine Wave |
Efficiency |
|
ECO Mode (Advanced) |
98% |
Battery Mode |
89% |
Battery |
|
Standard Model |
Battery Type & Number: 12V x 9AH (x 4) |
Additional Battery Banks |
PSRTBB8 (x1) |
Protection |
|
Full Protection |
Overload, discharge, thermal, short circuit and overcharge protection |
Surge Protection |
1560J/32500A |
Communications & Management |
|
Interface |
USB or RS232 as standard, Intelligent slot for PSSNMP, PSModbus or PSAS400 dry contact |
Software |
PowerShield NetGuard® software - supports Windows based operating systems, Linux, Unix and Mac |
LCD Display/Alarm |
AC Mode, Batt.Mode, Load Level, Input Voltage, Output Voltage, Overload, Fault, Low Batt, Batt.Time Remaining |
Audible Alarm |
Battery Mode, Low Battery (Batt. Mode), Fault, Overload |
Physical |
|
Dimension (D x W x H) |
480 x 438 x 88mm |
Weight (Net/Gross) |
(23kg/25kg) |
Operating Environment |
|
Temperature |
0 - 40°C |
Humidity |
0 - 90% (RH Non-condensing) |
Noise Level |
<45dB |
Compliance |
|
Safety |
EN62040-1-1 2003, IEC60950-1-1 |
EMC |
EN62040-2 2006 |
RoHS |
Directive 2011/65/EU |