Powershield PSCERT2000SB Centurion RT 2000VA Short Base Double Conversion True Online UPS
The Centurion RT Short Base (SB) Model is perfect for COMMS Racks with a shorter base and designed to fit most equipment racks.
As a true online double conversion UPS the Centurion RT is Powershield's highest single phase power density UPS. Boasting an output power factor of 0.9, this will fully protect mission critical devices as it can support larger loads than UPS products of an equal VA rating.
The Centurion RT has an energy saving Advanced ECO mode, which allows the unit to operate at very high efficiency, up to 98%. When the utility mains input voltage is within the ECO range the UPS saves energy by passing the mains supply directly through to the load, while the inverter continues to operate in a passive mode.
- True double-conversion
- Output power factor 0.9
- User-friendly and electronic easy-shift LCD display
- Rack or Tower design
- Advanced ECO mode for energy saving
- Generator compatible
- Programmable power management outlets
- Emergency Power Off function (EPO)
- Hot swappable battery design
- Available in 1000, 2000 and 3000 VA models
- Ideal for medium density power protection
- 24 Months (extended to 36 Months with product registration)
SB = Short Base. Rack Tower UPS. Battery 4 x 12V 9AH.
Capacity |
2000VA/1800W |
Topology |
True online double- conversion, Pure Sine Wave |
Input |
|
Voltage Range |
Low Line Transfer: 160Vac/140Vac/120/110Vac ±5% (based on load percentage 100%-80%/80%-70%/70%-60%/60%-0) Low Line Comeback: 175Vac/155Vac/135Vac/125Vac ±5 % High Line Transfer: 300Vac ±5 % High Line Comeback: 290Vac ±5 % |
Frequency Range |
40Hz - 70Hz |
Phase |
Single-phase with ground |
Power Factor Correction |
≤0.99 @ nominal voltage (100% load) |
Output |
|
Output Power Factor |
0.9 |
Output Voltage (AC Mode) |
240Vac (Selectable 200/208/220/230/240Vac) |
Voltage Regulation (Batt. Mode) |
±1% |
Frequency Range (Batt. Mode) |
50Hz or 60Hz ±1Hz |
Current Crest Ratio |
3:1 (max.) |
Transfer |
AC Mode to Batt. Mode: 0 |
Waveform (Batt. Mode) |
Pure Sine Wave |
Efficiency |
|
ECO Mode (Advanced) |
97% |
Battery Mode |
87% |
Battery |
|
Battery Number (12 V*9AH) |
x4 |
Typical Recharge Time |
4 hours recover to 90% capacity (for standard model only) |
Charging Current (max.) |
Standard Models - 1.5Amp. Long Run Models - 1Amp/2Amp/4Amp/6Amp selectable (factory default is 6Amp) |
Protection |
|
Full Protection |
Overload, discharge, thermal, short circuit and overcharge protection |
Surge Protection |
984 Joules/22000 Amps |
Communications and Management |
|
Interface |
USB or RS232 as standard, Intelligent slot for PSSNMP, PSModbus or PSAS400 dry contact |
Software |
PowerShield® NetGuard® software - supports Windows, Linux, Unix and Mac-based operating systems |
LCD Display/Alarm |
UPS Status, Load & Battery Level, Input/Output Voltage, Batt. Time Remaining and Fault Indicators |
Audible Alarm |
Battery Mode, Bypass Mode, Low Battery (Batt. Mode), Fault, Overload |
Physical |
|
Dimension, (D x W x H) mm |
500 x 438 x 88 |
Weight (kg) |
19.5 |
Operating Environment |
|
Temperature |
0°C ~ 40°C |
Humidity |
20% ~ 90% (RH Non-condensing) |
Noise Level |
<50dBA@1m |
Compliance |
|
Safety/EMC/RoHS |
EN62040-1-1 2003, IEC60950-1-1/EN62040-2 2006/Directive 2011/65/EU |
Capacity |
2000VA/1800W |
Topology |
True online double- conversion, Pure Sine Wave |
Input |
|
Voltage Range |
Low Line Transfer: 160Vac/140Vac/120/110Vac ±5% (based on load percentage 100%-80%/80%-70%/70%-60%/60%-0) Low Line Comeback: 175Vac/155Vac/135Vac/125Vac ±5 % High Line Transfer: 300Vac ±5 % High Line Comeback: 290Vac ±5 % |
Frequency Range |
40Hz - 70Hz |
Phase |
Single-phase with ground |
Power Factor Correction |
≤0.99 @ nominal voltage (100% load) |
Output |
|
Output Power Factor |
0.9 |
Output Voltage (AC Mode) |
240Vac (Selectable 200/208/220/230/240Vac) |
Voltage Regulation (Batt. Mode) |
±1% |
Frequency Range (Batt. Mode) |
50Hz or 60Hz ±1Hz |
Current Crest Ratio |
3:1 (max.) |
Transfer |
AC Mode to Batt. Mode: 0 |
Waveform (Batt. Mode) |
Pure Sine Wave |
Efficiency |
|
ECO Mode (Advanced) |
97% |
Battery Mode |
87% |
Battery |
|
Battery Number (12 V*9AH) |
x4 |
Typical Recharge Time |
4 hours recover to 90% capacity (for standard model only) |
Charging Current (max.) |
Standard Models - 1.5Amp. Long Run Models - 1Amp/2Amp/4Amp/6Amp selectable (factory default is 6Amp) |
Protection |
|
Full Protection |
Overload, discharge, thermal, short circuit and overcharge protection |
Surge Protection |
984 Joules/22000 Amps |
Communications and Management |
|
Interface |
USB or RS232 as standard, Intelligent slot for PSSNMP, PSModbus or PSAS400 dry contact |
Software |
PowerShield® NetGuard® software - supports Windows, Linux, Unix and Mac-based operating systems |
LCD Display/Alarm |
UPS Status, Load & Battery Level, Input/Output Voltage, Batt. Time Remaining and Fault Indicators |
Audible Alarm |
Battery Mode, Bypass Mode, Low Battery (Batt. Mode), Fault, Overload |
Physical |
|
Dimension, (D x W x H) mm |
500 x 438 x 88 |
Weight (kg) |
19.5 |
Operating Environment |
|
Temperature |
0°C ~ 40°C |
Humidity |
20% ~ 90% (RH Non-condensing) |
Noise Level |
<50dBA@1m |
Compliance |
|
Safety/EMC/RoHS |
EN62040-1-1 2003, IEC60950-1-1/EN62040-2 2006/Directive 2011/65/EU |