Powershield PSCE3000 Centurion Tower 3000VA / 2700W Double Conversion True Online UPS

Please feel free to contact us about this item, and we will recommend an IT Sales and Service Provider in your area.


Resellers: for pricing and to place orders.

This item is not normally held in stock. We’ll order it in on request. Please contact us for estimated delivery time
In stock email will be sent.
Instock notification already exists.
Order SKU: Supplier Code:

The PowerShield Centurion UPS provides a permanent backup power solution for sensitive devices such as medical equipment and internet routers.

Use Power Shield Centurion to protect:
Servers
Critical power applications
Items in remote areas (over 30 kms outside of city grid)
Where light to heavy industrial equipment is utilised
Where generators are present
Applications that require remote connectivity

Key Features

  • True Online Double Conversion
  • Wide input voltage range
  • Input power factor correction 0.98
  • 50Hz/60Hz frequency converter mode
  • Programmable power outlets
  • Emergency power off function (EPO)
  • Optional Eco-mode operation for energy saving
  • Generator compatible
  • Backup time for all models is easily extended by simply plugging additional battery banks
  • Battery banks are available with internal charger to enable fast recharge even with large battery banks
  • USB, RS232, SNMP and AS400 multiple communications available
  • Extendable maintenance bypass available for all models
  • N+X parallel redundancy available for 6K/10K model
  • 2 Year Warranty

INPUT

Voltage Range

Low Line Transfer

160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5%
(based on load percentage 100% - 80% / 80% - 70%
/ 70% - 60% / 60% - 0%)

Low Line Comeback 

175 VAC ± 5%

High Line Transfer

300 VAC ± 5%

High Line Comeback

47.5Hz ~ 52.5 Hz or 57Hz ~ 63Hz

Frequency Range

47.5Hz ~ 52.5 Hz or 57Hz ~ 63Hz

Phase

Single phase with ground

Power Factor

0.98

OUTPUT

AC Voltage Regulation (Batt. Mode) 

± 3%

Frequency Range (Synchronized Range  

48Hz ~ 52Hz or 57Hz ~ 63Hz

Frequency Range (Batt. Mode)

50Hz ± 0.25Hz or 60Hz ± 0.3Hz

Load Crest Factor

3:1

Harmonic Distortion

4% THD (Linear Load)  

7% THD (Non-linear Load)

Transfer

AC Mode to Batt. Mode 

Zero

Inverter to Bypass

4ms (Typical)

Waveform (Batt. Mode)

Pure Sinewave

EFFICIENCY

ECO Mode

88%

Battery Mode

83%

BATTERY

Battery Type

12Vx9AH (x6)

Typical Recharge Time

4 Hours to Recover to 90% Capacity

Charging Time (Max.)

1.0A

Charging Voltage

82.1 VDC ± 1%

PROTECTION

Full Protection

Overload, discharge, thermal, short circuit
and overcharge protection

COMMUNICATIONS & MANAGEMENT

Interface

USB or RS232 as standard, Intelligent slot for PSSNMP
or PSA400 dry contact

Software

Power Shield NetGuard Software - supports
Windows based operating Systems, Linux, Unix & Mac

LCD Display / Alarm

UPS Status, Load Level, Battery Level, Input/Output Voltage,
Battery Time Remaining and Fault Indicators

Audible Alarm

Battery Mode, Low Battery, Overload, Fault

PHYSICAL

Dimension (D x W x H)

425 x 190 x 335mm

Weight

28kg

OPERATING ENVIRONMENT

Temperature

0°C - 40°C

Humidity

20-90% (RH Non-condensing)

Noise Level

Less than 45dBA @ 1 Meter

COMPLIANCE

Safety

EN62040-1-1 2003, IEC60950-1-1

EMS

EN62040-2 2006

RoHS

Directive 2001 / 65 / EU

INPUT

Voltage Range

Low Line Transfer

160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5%
(based on load percentage 100% - 80% / 80% - 70%
/ 70% - 60% / 60% - 0%)

Low Line Comeback 

175 VAC ± 5%

High Line Transfer

300 VAC ± 5%

High Line Comeback

47.5Hz ~ 52.5 Hz or 57Hz ~ 63Hz

Frequency Range

47.5Hz ~ 52.5 Hz or 57Hz ~ 63Hz

Phase

Single phase with ground

Power Factor

0.98

OUTPUT

AC Voltage Regulation (Batt. Mode) 

± 3%

Frequency Range (Synchronized Range  

48Hz ~ 52Hz or 57Hz ~ 63Hz

Frequency Range (Batt. Mode)

50Hz ± 0.25Hz or 60Hz ± 0.3Hz

Load Crest Factor

3:1

Harmonic Distortion

4% THD (Linear Load)  

7% THD (Non-linear Load)

Transfer

AC Mode to Batt. Mode 

Zero

Inverter to Bypass

4ms (Typical)

Waveform (Batt. Mode)

Pure Sinewave

EFFICIENCY

ECO Mode

88%

Battery Mode

83%

BATTERY

Battery Type

12Vx9AH (x6)

Typical Recharge Time

4 Hours to Recover to 90% Capacity

Charging Time (Max.)

1.0A

Charging Voltage

82.1 VDC ± 1%

PROTECTION

Full Protection

Overload, discharge, thermal, short circuit
and overcharge protection

COMMUNICATIONS & MANAGEMENT

Interface

USB or RS232 as standard, Intelligent slot for PSSNMP
or PSA400 dry contact

Software

Power Shield NetGuard Software - supports
Windows based operating Systems, Linux, Unix & Mac

LCD Display / Alarm

UPS Status, Load Level, Battery Level, Input/Output Voltage,
Battery Time Remaining and Fault Indicators

Audible Alarm

Battery Mode, Low Battery, Overload, Fault

PHYSICAL

Dimension (D x W x H)

425 x 190 x 335mm

Weight

28kg

OPERATING ENVIRONMENT

Temperature

0°C - 40°C

Humidity

20-90% (RH Non-condensing)

Noise Level

Less than 45dBA @ 1 Meter

COMPLIANCE

Safety

EN62040-1-1 2003, IEC60950-1-1

EMS

EN62040-2 2006

RoHS

Directive 2001 / 65 / EU