Powershield PSCERT6000L Centurion RT 6000VA Long run model True On-line double conversion Rack/Tower UPS
The Centurion RT features true online double conversion. As our highest single phase power density UPS, this sophisticated range will provide the most comprehensive protection for mission critical devices such as sensitive networks, computers, servers, telecom applications, as well as industrial applications.
- True online double-conversion
- Exceptional surge protection
- Easy-shift LCD display
- Rack or tower design
- Emergency power off function
- Eco and advanced ECO mode operation for energy saving
- Standard extra large charger
- How swappable batteries
- 2 Year Warranty
INPUT |
||
Voltage Range |
Line Loss |
110V~300V AC@(0~60%) Load; 140V~300V @(60~80%) Load; 176V~300V AC@(80~100%) Load |
Low Line Comeback |
Low Line Loss Voltage +10V |
|
High Line Comeback |
High Line Loss Voltage -10V |
|
Frequency Range |
46Hz~54Hz@50Hz system; 56Hz~64Hz@60Hz system |
|
Phase |
Single phase with ground |
|
Power Factor Correction |
≤0.99@nominal voltage (100% load) |
|
OUTPUT |
Output Power Factor: 0.9 |
|
Output Voltage |
208/220/230/240V AC Selectable |
|
AC Voltage Regulation |
±1% |
|
Frequency Range (Synchronized Range) |
46Hz~54Hz@50Hz system |
|
Frequency Range (Batt. Mode) |
50Hz±0.1Hz or 60Hz±0.1Hz |
|
Overload |
AC Mode: 100%~110%: 10min; 110%~130%: 1min; >130%: 1sec |
|
Current Crest Ratio |
3:1 (max.) |
|
Harmonic Distortion |
≤1% @ 100% Linear Load; ≤4% @100% Non-linear Load |
|
Transfer Time |
Line to Battery: 0ms |
|
EFFICIENCY |
||
ECO Mode (Advanced) |
<94% |
|
Battery Mode |
<93% |
|
BATTERY |
||
Battery Number |
Optional strings of 16 or 20 batteries |
|
Typical Recharge Time |
According to an external battery pack |
|
Charging Current (max.) |
4A ± 10% |
|
COMMUNICATIONS & MANAGEMENT |
||
Interface |
USB and RS232 as standard |
|
Software |
PowerShield® NetGuard® software - supports Windows, Linux, Unix and Mac based operating systems |
|
Optional |
Intelligent slot for PSSNMPV4, PSModbus or PSAS400 dry contact |
|
PHYSICAL |
||
Dimensions (D x W x H) |
UPS Unit: 600x438x88mm [2U] (weight: 17kg) |
|
OPERATING ENVIRONMENT |
||
Temperature |
0°C~40°C |
|
Humidity |
95% (RH Non-condensing) |
|
Altitude |
<1000m |
|
Noise Level |
Less than 55dB@1m |
INPUT |
||
Voltage Range |
Line Loss |
110V~300V AC@(0~60%) Load; 140V~300V @(60~80%) Load; 176V~300V AC@(80~100%) Load |
Low Line Comeback |
Low Line Loss Voltage +10V |
|
High Line Comeback |
High Line Loss Voltage -10V |
|
Frequency Range |
46Hz~54Hz@50Hz system; 56Hz~64Hz@60Hz system |
|
Phase |
Single phase with ground |
|
Power Factor Correction |
≤0.99@nominal voltage (100% load) |
|
OUTPUT |
Output Power Factor: 0.9 |
|
Output Voltage |
208/220/230/240V AC Selectable |
|
AC Voltage Regulation |
±1% |
|
Frequency Range (Synchronized Range) |
46Hz~54Hz@50Hz system |
|
Frequency Range (Batt. Mode) |
50Hz±0.1Hz or 60Hz±0.1Hz |
|
Overload |
AC Mode: 100%~110%: 10min; 110%~130%: 1min; >130%: 1sec |
|
Current Crest Ratio |
3:1 (max.) |
|
Harmonic Distortion |
≤1% @ 100% Linear Load; ≤4% @100% Non-linear Load |
|
Transfer Time |
Line to Battery: 0ms |
|
EFFICIENCY |
||
ECO Mode (Advanced) |
<94% |
|
Battery Mode |
<93% |
|
BATTERY |
||
Battery Number |
Optional strings of 16 or 20 batteries |
|
Typical Recharge Time |
According to an external battery pack |
|
Charging Current (max.) |
4A ± 10% |
|
COMMUNICATIONS & MANAGEMENT |
||
Interface |
USB and RS232 as standard |
|
Software |
PowerShield® NetGuard® software - supports Windows, Linux, Unix and Mac based operating systems |
|
Optional |
Intelligent slot for PSSNMPV4, PSModbus or PSAS400 dry contact |
|
PHYSICAL |
||
Dimensions (D x W x H) |
UPS Unit: 600x438x88mm [2U] (weight: 17kg) |
|
OPERATING ENVIRONMENT |
||
Temperature |
0°C~40°C |
|
Humidity |
95% (RH Non-condensing) |
|
Altitude |
<1000m |
|
Noise Level |
Less than 55dB@1m |