Powershield PSCE6000 Centurion Tower 6kVA/ 4800W. Double Conversion True Online UPS. Hardwired input & outputs
Centurion Tower 6kVA/ 4800W Double Conversion True Online UPS. Hardwired input & outputs. EBM Compatible for Extended Runtime. Multiple Communications. Requires 40A Circuit
The Centurion is designed to protect the critical computer, communications, industrial, medical and other mission critical equipment.
A true online double conversion UPS, the Centurion is designed to guarantee trouble-free operation of protected equipment in any harsh electrical environment. Versatile management and hardware options offer the flexibility to build up a power protection solution to fit any application. This range now comes with two sets of sockets on the back, one row of output sockets are programmable meaning that you can shed less important loads. This will leave additional valuable backup time to the equipment that is most critical. This UPS includes a stylish, informative LCD display.
- True Online Double Conversion
- Wide input voltage range (110-300 VAC)
- Input power factor correction 0.98
- 50Hz/ 60Hz frequency converter mode
- Programmable power outlets
- Emergency power off function (EPO)
- Optional Eco-mode operation for energy saving
- Generator compatible
- Backup time for all models is easily extended by simply plugging additional battery banks
- Charger capacity expansion to 9A for long-run models
- USB RS232, SNMP and AS400 multiple communications available
- External maintenance bypass available for all models
- N + X parallel redundancy available for 6K / 10K models
- Monitoring and Shutdown Software included
INPUT |
||
Voltage Range |
Low Line Transfer |
176VAC @ 100% load |
Low Line Comeback |
186VAC @ 100% load |
|
High Line Transfer |
300VAC |
|
High Line Comeback |
290VAC |
|
Frequency Range |
46Hz~54Hz " 50Hz / 56Hz~64Hz " 60Hz |
|
Phase |
Single phase with ground |
|
Power Factor |
0.99 @ 100%load |
|
OUTPUT |
||
AC Voltage Regulation (Batt. Mode) |
± 1% |
|
Frequency Range (Synchronized Range) |
46Hz ~ 54Hz 50Hz/56Hz~64Hz 60Hz |
|
Frequency Range (Batt.Mode) |
50Hz ± 0.1Hz or 60Hz ± 0.1Hz |
|
Load Crest Factor |
3:1 |
|
Harmonic Distortion |
2% THD (Linear Load) |
|
Transfer |
AC Mode to Batt. Mode |
Zero |
Inverter to Bypass |
Zero |
|
Waveform (Batt. Mode) |
Pure Sinewave |
|
EFFICIENCY |
||
ECO Mode |
90% |
|
Battery Mode |
88% |
|
BATTERY |
|
|
Battery Type |
12Vx9AH (x20) |
|
Typical Recharge Time |
7 hours recover to 90% capacity |
|
Charging Current (Max.) |
1.0A |
|
Charging Voltage |
273.0 VDC |
|
PROTECTION |
||
Full Protection |
Overload, discharge, thermal, |
|
COMMUNICATIONS & MANAGEMENT |
||
Interface |
USB or RS232 as standard, |
|
Software |
Power Shield NetGuard Software - |
|
LCD Display / Alarm |
UPS Status, Load Level, Battery Level, |
|
Audible Alarm |
Battery Mode, Low Battery, Overload, Fault |
|
PHYSICAL |
||
Dimension (D x W x H) |
575 x 250 x 576.5mm |
|
Weight |
90kg/35kg |
|
OPERATING ENVIRONMENT |
||
Temperature |
0°C - 40°C |
|
Humidity |
20% - 90% (RH Non-Condensing) |
|
Noise Level |
Less than 55dB @ 1 Meter |
|
COMPLIANCE |
||
Safety |
EN62040-1-1 2003, IEC60950-1-1 |
|
EMS |
EN62040-2 2006 |
|
RoHS |
Directive 2001 / 65 / EU |
INPUT |
||
Voltage Range |
Low Line Transfer |
176VAC @ 100% load |
Low Line Comeback |
186VAC @ 100% load |
|
High Line Transfer |
300VAC |
|
High Line Comeback |
290VAC |
|
Frequency Range |
46Hz~54Hz " 50Hz / 56Hz~64Hz " 60Hz |
|
Phase |
Single phase with ground |
|
Power Factor |
0.99 @ 100%load |
|
OUTPUT |
||
AC Voltage Regulation (Batt. Mode) |
± 1% |
|
Frequency Range (Synchronized Range) |
46Hz ~ 54Hz 50Hz/56Hz~64Hz 60Hz |
|
Frequency Range (Batt.Mode) |
50Hz ± 0.1Hz or 60Hz ± 0.1Hz |
|
Load Crest Factor |
3:1 |
|
Harmonic Distortion |
2% THD (Linear Load) |
|
Transfer |
AC Mode to Batt. Mode |
Zero |
Inverter to Bypass |
Zero |
|
Waveform (Batt. Mode) |
Pure Sinewave |
|
EFFICIENCY |
||
ECO Mode |
90% |
|
Battery Mode |
88% |
|
BATTERY |
|
|
Battery Type |
12Vx9AH (x20) |
|
Typical Recharge Time |
7 hours recover to 90% capacity |
|
Charging Current (Max.) |
1.0A |
|
Charging Voltage |
273.0 VDC |
|
PROTECTION |
||
Full Protection |
Overload, discharge, thermal, |
|
COMMUNICATIONS & MANAGEMENT |
||
Interface |
USB or RS232 as standard, |
|
Software |
Power Shield NetGuard Software - |
|
LCD Display / Alarm |
UPS Status, Load Level, Battery Level, |
|
Audible Alarm |
Battery Mode, Low Battery, Overload, Fault |
|
PHYSICAL |
||
Dimension (D x W x H) |
575 x 250 x 576.5mm |
|
Weight |
90kg/35kg |
|
OPERATING ENVIRONMENT |
||
Temperature |
0°C - 40°C |
|
Humidity |
20% - 90% (RH Non-Condensing) |
|
Noise Level |
Less than 55dB @ 1 Meter |
|
COMPLIANCE |
||
Safety |
EN62040-1-1 2003, IEC60950-1-1 |
|
EMS |
EN62040-2 2006 |
|
RoHS |
Directive 2001 / 65 / EU |