Powershield PSCERT3000L Centurion RT 3000VA/ Long Run Online UPS. No Internal Batteries

Please feel free to contact us about this item, and we will recommend an IT Sales and Service Provider in your area.


Resellers: for pricing and to place orders.

In stock email will be sent.
Instock notification already exists.
Order SKU: Supplier Code:

Centurion RT 3000VA/ Long Run Online UPS. NO INTERNAL Batteries, PSRTBB12 or External battery bank must be used.

PowerShield Centurion RT 2000VA/ Long Run Online UPS. No Internal Batteries, PSRTBB12 or External battery bank must be used.

As a true online double conversion UPS the Centurion RT is our highest single phase power density UPS. Boasting an output power factor of 0.9, this will fully protect mission critical devices as it can support larger loads than UPS products of an equal VA rating.
The Centurion RT has an energy saving Advanced ECO mode, which allows the unit to operate at very high efficiency, up to 98%. When the utility mains input voltage is within the ECO range the UPS saves energy by passing the mains supply directly through to the load, while the inverter continues to operate in a passive mode .

  • True double-conversion
  • Output power factor 0.9
  • User-friendly and electronic easy-shift LCD display
  • Rack or Tower design
  • Advanced ECO mode for energy saving
  • Generator compatible
  • Programmable power management outlets
  • Emergency Power Off function (EPO)
  • Hot swappable battery design
  • Available in 2000 VA models
  • Ideal for medium density power protectioncan be
  • Extra large charger

Capacity

3000VA/2700W

Topology

True online double- conversion, Pure Sine Wave

INPUT

Voltage Range

Low Line Transfer

160Vac / 140Vac / 120 / 110Vac ± 5 % (based on load percentage 100%-80% / 80%-70% / 70%-60% / 60%-0)

Low Line Comeback

175Vac / 155Vac / 135Vac / 125Vac ± 5 %

High Line Transfer

300Vac ± 5 %

High Line Comeback

290Vac ± 5 %

Frequency Range

40Hz - 70Hz

Phase

Single phase with ground

Power Factor Correction

>0.99 @ nominal voltage (100% load)

OUTPUT

Output Power Factor

0.9

Output Voltage (AC Mode)

240Vac (Selectable 200/208/220/230/240Vac)

Voltage Regulation (Batt. Mode)

± 1%

Frequency Range (Batt. Mode)

50Hz or 60Hz ±1Hz

Current Crest Ratio

3:1 (max.)

Transfer

AC Mode to Batt. Mode

Zero

Inverter to Bypass

4ms (Typical)

Waveform (Batt. Mode)

Pure Sine Wave

EFFICIENCY

ECO Mode (Advanced)

97%

Battery Mode

87%

 BATTERY  

 Battery Number (12 V*9AH) 

 x 6

 Typical Recharge Time 

 4 hours recover to 90% capacity (for standard model only)

 Charging Current (max.) 

 Standard Models - 1.5Amp. Long Run Models - 1Amp / 2Amp / 4Amp / 6Amp selectable (factory default is 6Amp)

 PROTECTION  

 Full Protection 

Overload, discharge, thermal, short circuit and overcharge protection

 Surge Protection 

 984 Joules / 22000 Amps

 COMMUNICATIONS AND MANAGMENT  

 Interface 

USB or RS232 as standard, Intelligent slot for PSSNMP, PSModbus or PSAS400 dry contact

 Software 

PowerShield® NetGuard® software - supports Windows, Linux, Unix and Mac based operating systems

 LCD Display/Alarm 

UPS Status, Load & Battery Level, Input/Output Voltage, Batt. Time Remaining and Fault Indicators

 Audible Alarm 

 Battery Mode, Bypass Mode, Low Battery (Batt. Mode), Fault, Overload

 PHYSICAL  

 Dimension, (D x W x H) mm 

 600 x 438 x 88

 Weight (kg) 

 26.8 & 11.6

 OPERATING ENVIRONMENT   

 Temperature 

 0 - 40°C

 Humidity 

 20 - 90% (RH Non-condensing)

 Noise Level 

 < 50dBA @ 1 Meter

 COMPLIANCE  

 Safety / EMC / RoHS 

 EN62040-1-1 2003, IEC60950-1-1 / EN62040-2 2006 / Directive 2011/65/EU

Capacity

3000VA/2700W

Topology

True online double- conversion, Pure Sine Wave

INPUT

Voltage Range

Low Line Transfer

160Vac / 140Vac / 120 / 110Vac ± 5 % (based on load percentage 100%-80% / 80%-70% / 70%-60% / 60%-0)

Low Line Comeback

175Vac / 155Vac / 135Vac / 125Vac ± 5 %

High Line Transfer

300Vac ± 5 %

High Line Comeback

290Vac ± 5 %

Frequency Range

40Hz - 70Hz

Phase

Single phase with ground

Power Factor Correction

>0.99 @ nominal voltage (100% load)

OUTPUT

Output Power Factor

0.9

Output Voltage (AC Mode)

240Vac (Selectable 200/208/220/230/240Vac)

Voltage Regulation (Batt. Mode)

± 1%

Frequency Range (Batt. Mode)

50Hz or 60Hz ±1Hz

Current Crest Ratio

3:1 (max.)

Transfer

AC Mode to Batt. Mode

Zero

Inverter to Bypass

4ms (Typical)

Waveform (Batt. Mode)

Pure Sine Wave

EFFICIENCY

ECO Mode (Advanced)

97%

Battery Mode

87%

 BATTERY  

 Battery Number (12 V*9AH) 

 x 6

 Typical Recharge Time 

 4 hours recover to 90% capacity (for standard model only)

 Charging Current (max.) 

 Standard Models - 1.5Amp. Long Run Models - 1Amp / 2Amp / 4Amp / 6Amp selectable (factory default is 6Amp)

 PROTECTION  

 Full Protection 

Overload, discharge, thermal, short circuit and overcharge protection

 Surge Protection 

 984 Joules / 22000 Amps

 COMMUNICATIONS AND MANAGMENT  

 Interface 

USB or RS232 as standard, Intelligent slot for PSSNMP, PSModbus or PSAS400 dry contact

 Software 

PowerShield® NetGuard® software - supports Windows, Linux, Unix and Mac based operating systems

 LCD Display/Alarm 

UPS Status, Load & Battery Level, Input/Output Voltage, Batt. Time Remaining and Fault Indicators

 Audible Alarm 

 Battery Mode, Bypass Mode, Low Battery (Batt. Mode), Fault, Overload

 PHYSICAL  

 Dimension, (D x W x H) mm 

 600 x 438 x 88

 Weight (kg) 

 26.8 & 11.6

 OPERATING ENVIRONMENT   

 Temperature 

 0 - 40°C

 Humidity 

 20 - 90% (RH Non-condensing)

 Noise Level 

 < 50dBA @ 1 Meter

 COMPLIANCE  

 Safety / EMC / RoHS 

 EN62040-1-1 2003, IEC60950-1-1 / EN62040-2 2006 / Directive 2011/65/EU