Powershield PSD650 Defender 650VA UPS, 2x 3-Pin Outlet Plugs
The Defender range uses Automatic Voltage Regulation (AVR) to minimise the effects of ?uctuations in input voltage protecting your valuable equipment from power line disturbances.The stylish LCD display, user replaceable batteries and Australian/New Zealand sockets makes the Defender the complete package at this level.
- Stylish and informative LCD display
- Surge Protection, Best in its Class
- Excellent microprocessor control guarantees high reliability
- Australian outlets for UPS and Surge Protection
- Boost and buck AVR for voltage stabilization
- User replaceable batteries
- Silent Operation (No fans included)
- Auto restart while AC is recovering
- Off-mode charging
- Cold start function
- USB communication with sophisticated NetGuard software
- FREE download software
- The Defender USB communication port is compatible with Synology and QNAP NAS products.
- 2 Year Warranty
SPECIFICATIONS |
|
Capacity |
650V A / 390 W |
Topology |
Line Interactive |
INPUT |
|
Voltage |
240V AC (Nominal) |
Voltage Range |
177-290V AV |
Frequency Range |
50/60Hz±5Hz (Auto Sensing) |
OUTPUT |
|
Output Voltage |
240Vac±10% |
Frequency |
AC mode tracks utility. |
Frequency Range |
50Hz or 60Hz±1Hz |
Transfer Time |
6ms (Typical) |
Waveform (Battery Mode) |
Simulated Sine Wave |
Outlets |
2x Surge Protection + UPS |
BATTERY |
|
Battery Type & Number |
12Vx9AH (x1) |
Typical Recharge Time |
6 hours recovery to 90% capacity |
Backup Time (50% Load) |
13min |
PROTECTION |
|
Full Protection |
Overload, discharge, thermal, |
Surge Protection |
312Joules / 6500Amps |
COMMUNICATIONS & MANAGEMENT |
|
Interface |
USB Interface |
Software |
NetGuard® supports Windows®, |
LCD Alarm |
AC Mode, Battery Mode, Low Battery |
Audible Alarm |
Battery Mode, Low Battery (Batt. Mode), |
PHYSICAL |
|
Dimensions (D x W x H) |
328 x 100 x 145mm |
Net Weight |
5.2kg |
Temperature |
0°C - 40°C |
Humidity |
0% - 90% (RH Non-Condensing) |
Noise Level |
<5dB (no fan) |
COMPLIANCE |
|
Safety |
EN62040-1-1 2003. IEC60950-1 : 2001 |
EMC |
EN62040-2 2006 |
RoHS |
Directive 2011 / 65 / EU |
SPECIFICATIONS |
|
Capacity |
650V A / 390 W |
Topology |
Line Interactive |
INPUT |
|
Voltage |
240V AC (Nominal) |
Voltage Range |
177-290V AV |
Frequency Range |
50/60Hz±5Hz (Auto Sensing) |
OUTPUT |
|
Output Voltage |
240Vac±10% |
Frequency |
AC mode tracks utility. |
Frequency Range |
50Hz or 60Hz±1Hz |
Transfer Time |
6ms (Typical) |
Waveform (Battery Mode) |
Simulated Sine Wave |
Outlets |
2x Surge Protection + UPS |
BATTERY |
|
Battery Type & Number |
12Vx9AH (x1) |
Typical Recharge Time |
6 hours recovery to 90% capacity |
Backup Time (50% Load) |
13min |
PROTECTION |
|
Full Protection |
Overload, discharge, thermal, |
Surge Protection |
312Joules / 6500Amps |
COMMUNICATIONS & MANAGEMENT |
|
Interface |
USB Interface |
Software |
NetGuard® supports Windows®, |
LCD Alarm |
AC Mode, Battery Mode, Low Battery |
Audible Alarm |
Battery Mode, Low Battery (Batt. Mode), |
PHYSICAL |
|
Dimensions (D x W x H) |
328 x 100 x 145mm |
Net Weight |
5.2kg |
Temperature |
0°C - 40°C |
Humidity |
0% - 90% (RH Non-Condensing) |
Noise Level |
<5dB (no fan) |
COMPLIANCE |
|
Safety |
EN62040-1-1 2003. IEC60950-1 : 2001 |
EMC |
EN62040-2 2006 |
RoHS |
Directive 2011 / 65 / EU |